If Generator Does Not Charge

1. Brushes badly worn.

2. Brushes sticking in holders.

3. Voltage regulator not grounded.

4. Voltage regulator incorrectly adjusted.

5. Defective voltage regulator.

6. Commutator dirty or oily.

7. Positive brush holder grounded.

8. Generator "A" terminal grounded.

9. Loose or broken wire in generator-battery circuit.

10. Broken field coil wire or loose terminal (both coils).

11. Commutator shorted

12. Defective armature.

I? ©IW1IATOK CHARGING RATE IS

BELOW NQKftML

1. Voltage regulator incorrectly adjusted.

2. Broken field coil wire or loose terminal (one coii).

3. Commutator worn and not turning true with shaft - throws brushes at high speed.

4. Commutator dirty or oily.

5. Brushes gummy and sluggish in holders.

6. Defective armature.

0 0

Post a comment